启动慢Slow Startup

可能的原因建议的解决方案Possible CauseSuggested Remedies
启动时阀针式浇口留有空气• 在启动之前断开到阀针式浇口的空 气供应Valve gate air left on at startup• Shut off the air to the valve gates prior to startup
热流道加热器的电压低• 将电源电压稳定在额定电压Hot RunnerLow voltage to heaters• Stabilize the voltage supply to the rated voltage
因加热控制器要完成软启 动控制而延迟• 等待软启动以干燥加热器Delay due to completion of soft start controls on heat controller• Wait for soft start to dry out the heater
分流板加热器故障• 更换Faulty manifold heater• Replace
分流板热电偶故障或热电 偶接地故障Faulty manifold thermocouple or ground fault on thermocouple
系统发生塑料泄漏• 拆卸热流道,清洁、检查并更换损坏的 部件System has leaked plastic• Disassemble the hot runner, clean, check and replace any damaged components