浇口冻结Freezing of Gates

可能的原因建议的解决方案Possible CauseSuggested Remedies
浇口堵塞• 拆卸模腔板,并清洁浇口或更换注嘴Blocked gate• Remove cavity plate and clean gate or replace nozzle tip
模具注嘴加热器故障• 更换注嘴加热器MoldFailed nozzle heater• Replace heater on nozzle
分流板加热器故障• 更换分流板加热器Failed manifold heater• Replace heater on manifold
加热器锁紧装置松动• 拧紧Loose heater clamp• Tighten
热电偶故障注嘴• 更换注嘴热电偶Thermocouple faultNozzle• Replace nozzle thermocouple
分流板• 用备件更换分流板热电偶Manifold• Replace manifold thermocouple with spare
阀针不工作• 清洁或更换阀针Valve stem not functioning• Clean or replace the valve stem
浇口损坏,无法拉出• 按照规格更换或重新加工浇口杯Gate not to drawing due to damage• Replace or rework the gate detail to specifications
注嘴损坏• 更换注嘴。参见第 5.2.8 节。Nozzle tipDamaged• Replace the nozzle tip. Refer toSection 5.2.8.
注嘴安装有误• 安装合适的注嘴。参见第 5.2.8.3 节。Incorrect tip installed• Install the proper nozzle tip. Refer toSection 5.2.8.3.
接触浇口杯• 按照规格更换或维修浇口杯Touching gate detail• Replace or repair the gate detail to specifications
注嘴隔热帽损坏• 更换注嘴隔热帽。参见第 5.2.14 节。Damaged nozzle tip insulator• Replace the nozzle tip insulator. Refer toSection 5.2.14.
注嘴加热器碰触浇口杯• 重新定位注嘴加热器Nozzle heater touchingGate detail• Reposition the nozzle heater
Plate
分流板加热器端部与板接触• 弯曲分流板加热器Manifold heater end touching plate• Bend the manifold heater
工艺浇道、分流板或注嘴温度 过低• 提高温度设置ProcessingSprue, manifold or nozzle temperatures too low• Increase the temperature settings.
阀针式浇口• 增加气压Valve gate• Increase the air pressure.
• 改变空气阀顺序• Change the air valve sequence.