{"id":251,"date":"2024-10-26T13:46:18","date_gmt":"2024-10-26T05:46:18","guid":{"rendered":"https:\/\/www.laoni.work\/?post_type=epkb_post_type_1&#038;p=251"},"modified":"2024-11-21T15:53:24","modified_gmt":"2024-11-21T07:53:24","slug":"%e6%b5%87%e5%8f%a3%e5%86%bb%e7%bb%93freezing-of-gates","status":"publish","type":"epkb_post_type_1","link":"https:\/\/www.laoni.work\/?epkb_post_type_1=%e6%b5%87%e5%8f%a3%e5%86%bb%e7%bb%93freezing-of-gates","title":{"rendered":"\u6d47\u53e3\u51bb\u7ed3Freezing of Gates"},"content":{"rendered":"\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"2\">\u53ef\u80fd\u7684\u539f\u56e0<\/td><td>\u5efa\u8bae\u7684\u89e3\u51b3\u65b9\u6848<\/td><td colspan=\"2\">Possible Cause<\/td><td>Suggested Remedies<\/td><\/tr><tr><td colspan=\"2\">\u6d47\u53e3\u5835\u585e<\/td><td>\u2022&nbsp;\u62c6\u5378\u6a21\u8154\u677f\uff0c\u5e76\u6e05\u6d01\u6d47\u53e3\u6216\u66f4\u6362\u6ce8\u5634<\/td><td colspan=\"2\">Blocked gate<\/td><td>\u2022&nbsp;Remove cavity plate and clean gate or replace nozzle tip<\/td><\/tr><tr><td rowspan=\"2\">\u6a21\u5177<\/td><td>\u6ce8\u5634\u52a0\u70ed\u5668\u6545\u969c<\/td><td>\u2022&nbsp;\u66f4\u6362\u6ce8\u5634\u52a0\u70ed\u5668<\/td><td rowspan=\"2\">Mold<\/td><td>Failed nozzle heater<\/td><td>\u2022&nbsp;Replace heater on nozzle<\/td><\/tr><tr><td>\u5206\u6d41\u677f\u52a0\u70ed\u5668\u6545\u969c<\/td><td>\u2022&nbsp;\u66f4\u6362\u5206\u6d41\u677f\u52a0\u70ed\u5668<\/td><td>Failed manifold heater<\/td><td>\u2022&nbsp;Replace heater on manifold<\/td><\/tr><tr><td colspan=\"2\">\u52a0\u70ed\u5668\u9501\u7d27\u88c5\u7f6e\u677e\u52a8<\/td><td>\u2022&nbsp;\u62e7\u7d27<\/td><td colspan=\"2\">Loose heater clamp<\/td><td>\u2022&nbsp;Tighten<\/td><\/tr><tr><td rowspan=\"2\">\u70ed\u7535\u5076\u6545\u969c<\/td><td>\u6ce8\u5634<\/td><td>\u2022&nbsp;\u66f4\u6362\u6ce8\u5634\u70ed\u7535\u5076<\/td><td rowspan=\"2\">Thermocouple fault<\/td><td>Nozzle<\/td><td>\u2022&nbsp;Replace nozzle thermocouple<\/td><\/tr><tr><td>\u5206\u6d41\u677f<\/td><td>\u2022&nbsp;\u7528\u5907\u4ef6\u66f4\u6362\u5206\u6d41\u677f\u70ed\u7535\u5076<\/td><td>Manifold<\/td><td>\u2022&nbsp;Replace manifold thermocouple with spare<\/td><\/tr><tr><td colspan=\"2\">\u9600\u9488\u4e0d\u5de5\u4f5c<\/td><td>\u2022&nbsp;\u6e05\u6d01\u6216\u66f4\u6362\u9600\u9488<\/td><td colspan=\"2\">Valve stem not functioning<\/td><td>\u2022&nbsp;Clean or replace the valve stem<\/td><\/tr><tr><td colspan=\"2\">\u6d47\u53e3\u635f\u574f\uff0c\u65e0\u6cd5\u62c9\u51fa<\/td><td>\u2022&nbsp;\u6309\u7167\u89c4\u683c\u66f4\u6362\u6216\u91cd\u65b0\u52a0\u5de5\u6d47\u53e3\u676f<\/td><td colspan=\"2\">Gate not to drawing due to damage<\/td><td>\u2022&nbsp;Replace or rework the gate detail to specifications<\/td><\/tr><tr><td rowspan=\"4\">\u6ce8\u5634<\/td><td>\u635f\u574f<\/td><td>\u2022&nbsp;\u66f4\u6362\u6ce8\u5634\u3002\u53c2\u89c1\u7b2c&nbsp;5.2.8&nbsp;\u8282\u3002<\/td><td rowspan=\"4\">Nozzle tip<\/td><td>Damaged<\/td><td>\u2022&nbsp;Replace the nozzle tip. Refer toSection 5.2.8.<\/td><\/tr><tr><td>\u6ce8\u5634\u5b89\u88c5\u6709\u8bef<\/td><td>\u2022&nbsp;\u5b89\u88c5\u5408\u9002\u7684\u6ce8\u5634\u3002\u53c2\u89c1\u7b2c&nbsp;5.2.8.3&nbsp;\u8282\u3002<\/td><td>Incorrect tip installed<\/td><td>\u2022&nbsp;Install the proper nozzle tip. Refer toSection 5.2.8.3.<\/td><\/tr><tr><td>\u63a5\u89e6\u6d47\u53e3\u676f<\/td><td>\u2022&nbsp;\u6309\u7167\u89c4\u683c\u66f4\u6362\u6216\u7ef4\u4fee\u6d47\u53e3\u676f<\/td><td>Touching gate detail<\/td><td>\u2022&nbsp;Replace or repair the gate detail to specifications<\/td><\/tr><tr><td>\u6ce8\u5634\u9694\u70ed\u5e3d\u635f\u574f<\/td><td>\u2022&nbsp;\u66f4\u6362\u6ce8\u5634\u9694\u70ed\u5e3d\u3002\u53c2\u89c1\u7b2c&nbsp;5.2.14&nbsp;\u8282\u3002<\/td><td>Damaged nozzle tip insulator<\/td><td>\u2022&nbsp;Replace the nozzle tip insulator. Refer toSection 5.2.14.<\/td><\/tr><tr><td rowspan=\"2\">\u6ce8\u5634\u52a0\u70ed\u5668\u78b0\u89e6<\/td><td>\u6d47\u53e3\u676f<\/td><td rowspan=\"2\">\u2022&nbsp;\u91cd\u65b0\u5b9a\u4f4d\u6ce8\u5634\u52a0\u70ed\u5668<\/td><td rowspan=\"2\">Nozzle heater touching<\/td><td>Gate detail<\/td><td rowspan=\"2\">\u2022&nbsp;Reposition the nozzle heater<\/td><\/tr><tr><td>\u677f<\/td><td>Plate<\/td><\/tr><tr><td colspan=\"2\">\u5206\u6d41\u677f\u52a0\u70ed\u5668\u7aef\u90e8\u4e0e\u677f\u63a5\u89e6<\/td><td>\u2022&nbsp;\u5f2f\u66f2\u5206\u6d41\u677f\u52a0\u70ed\u5668<\/td><td colspan=\"2\">Manifold heater end touching plate<\/td><td>\u2022&nbsp;Bend the manifold heater<\/td><\/tr><tr><td rowspan=\"3\">\u5de5\u827a<\/td><td>\u6d47\u9053\u3001\u5206\u6d41\u677f\u6216\u6ce8\u5634\u6e29\u5ea6 \u8fc7\u4f4e<\/td><td>\u2022&nbsp;\u63d0\u9ad8\u6e29\u5ea6\u8bbe\u7f6e<\/td><td rowspan=\"3\">Processing<\/td><td>Sprue, manifold or nozzle temperatures too low<\/td><td>\u2022&nbsp;Increase the temperature settings.<\/td><\/tr><tr><td rowspan=\"2\">\u9600\u9488\u5f0f\u6d47\u53e3<\/td><td>\u2022&nbsp;\u589e\u52a0\u6c14\u538b<\/td><td rowspan=\"2\">Valve gate<\/td><td>\u2022&nbsp;Increase the air pressure.<\/td><\/tr><tr><td>\u2022&nbsp;\u6539\u53d8\u7a7a\u6c14\u9600\u987a\u5e8f<\/td><td>\u2022&nbsp;Change the air valve sequence.<\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p class=\"qua-blog-post-description\">\u53ef\u80fd\u7684\u539f\u56e0 \u5efa\u8bae\u7684\u89e3\u51b3\u65b9\u6848 Possible Cause Suggested Remedies \u6d47\u53e3\u5835\u585e \u2022&#038; [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"_bbp_topic_count":0,"_bbp_reply_count":0,"_bbp_total_topic_count":0,"_bbp_total_reply_count":0,"_bbp_voice_count":0,"_bbp_anonymous_reply_count":0,"_bbp_topic_count_hidden":0,"_bbp_reply_count_hidden":0,"_bbp_forum_subforum_count":0,"footnotes":""},"epkb_post_type_1_category":[40],"epkb_post_type_1_tag":[],"class_list":["post-251","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-mold-problem"],"_links":{"self":[{"href":"https:\/\/www.laoni.work\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/251","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.laoni.work\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/www.laoni.work\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/www.laoni.work\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.laoni.work\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=251"}],"version-history":[{"count":1,"href":"https:\/\/www.laoni.work\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/251\/revisions"}],"predecessor-version":[{"id":252,"href":"https:\/\/www.laoni.work\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/251\/revisions\/252"}],"wp:attachment":[{"href":"https:\/\/www.laoni.work\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=251"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/www.laoni.work\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=251"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/www.laoni.work\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=251"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}